因 安徽安庆抗震配件产品批次不同, 安徽安庆抗震配件原材料价格不同,具体详细价格请联系我们天津琪钰钢铁贸易有限公司的销售经理。
单位:Kg/m
壁 厚
外 径
3
3.5
4
4.5
5
5.5
6
32
2.146
2.460
2.762
3.052
3.329
3.594
3.847
38
2.589
2.978
3.354
3.718
4.069
4.408
4.735
42
2.885
3.323
3.749
4.162
4.562
4.951
5.327
45
3.107
3.582
4.044
4.495
4.932
5.358
5.771
50
3.477
4.014
4.538
5.049
5.549
6.036
6.511
54
3.773
4.359
4.932
5.493
6.042
6.578
7.103
57
3.995
4.618
5.228
5.826
6.412
6.985
7.546
60
4.217
4.877
5.524
6.159
6.782
7.392
7.990
63.5
4.476
5.179
5.869
6.548
7.214
7.867
8.508
68
4.809
5.567
6.313
7.047
7.768
8.477
9.174
70
4.957
5.740
6.511
7.269
8.015
8.749
9.470
73
5.179
5.999
6.807
7.602
8.385
9.156
9.914
76
5.401
6.258
7.103
7.935
8.755
9.563
10.358
89
6.363
7.380
8.385
9.378
10.358
11.326
12.281
108
7.768
9.020
10.259
11.486
12.701
13.903
15.093
133
11.178
12.725
14.261
15.783
17.294
18.792
159
13.422
15.290
17.146
18.989
20.821
22.639
219
18.601
21.209
23.805
26.388
28.959
31.517
273
23.262
26.536
29.797
33.046
36.283
39.508
325
27.750
31.665
35.568
39.458
43.337
47.202
355
38.897
43.158
47.406
51.641
377
41.339
45.871
50.390
54.897
426
46.777
51.913
57.036
62.147
450
480
530
6
八、 其他相关问题
1)焊缝的检测宜优先考虑受拉构件,在网架、桁架中应特别注意跨中下弦杆件。
2)钢结构工程施工质量验收规范?中不合格的处理
主控项目---- 必须 合格,不合格应处理。
一般项目 --- a.是否80%合格;
--- b.其余的20%是否满足允许偏差的1.2倍。
不合格项的处理办法:
a.返工,重做;
b.检测鉴定,满足设计要求,应予以验收;
c.检测鉴定不满足设计要求,经设计人员重新核算,满足要求,可予以验收;
d.设计人员认为不能满足要求,返修后二次验收可能引 起结构尺寸改变和功能发生变化,制定新的设计文件(加固方案),签订新的合同。施工单位按新的设计文件、合同进行验收,或 让步验收。
e. 不予验收
3)焊接材料的匹配
--- 不同母材焊接时的焊条选用,就低不就高的原则。
例如 钢梁 Q345,檩条Q235,用E43型焊条,不用E50型焊条
原因: a.焊接材料强度远比母材高
b.焊肉强度不能比母材高太多 (不大于50MPa)
4).建筑钢结构焊接技术规程?中关于焊缝的验收
a.抽检的焊缝数中,不合格率小于2%,该批定为合格;
b.抽检的焊缝数中,不合格率大于5%,该批定为不合格;
c.抽检的焊缝数中,不合格率为2%- 5% 时,应加倍抽检,且必须在原不合格部位两侧的焊缝处长线各增加一处,如在所有抽检焊缝中不合格率不大于3% ,该批定为合格,大于3% ,该批定为不合格。
当批量验收不合格时,应对该批余下的所有焊缝进行检测;